Radionuclide Information

NUCLIDE: H-3

TYPE(S) OF RADIATION
ENERGY
PERCENT DISINTEGRATION
RANGE IN AIR
RANGE IN WATER
SHIELDING REQUIRED






Beta
18.6 keV (max)
100%
6 mm
0.006 mm
None
 
Physical half-life 12.3 years


Survey instruments: none practical

Removable quantification method: smear and count in liquid scintillation counter


Personal dosimeter: none required

NUCLIDE: C-14

TYPE(S) OF RADIATION
ENERGY
PERCENT DISINTEGRATION
RANGE IN AIR
RANGE IN WATER
SHIELDING REQUIRED






Beta
156 keV (max)
100%
24 cm
0.28 mm
Plexiglass shielding reduces dose, but for microcurie amounts none is required


Physical half-life:  5730 years

Survey instruments:  GM use for gross contamination is possible, but efficiency is poor.

Removable quantification method: smear and count in liquid scintillation counter

Personal dosimeter: none required
 

NUCLIDE: S-35

TYPE(S) OF RADIATION
ENERGY
PERCENT DISINTEGRATION
RANGE IN AIR
RANGE IN WATER
SHIELDING REQUIRED






Beta
167 keV (max)
100%
26 cm
0.32 mm
Plexiglass shielding reduces dose, but for microcurie amounts none is required
 

Physical half-life:  87.4 days

Survey instruments:  GM use for gross contamination is possible, but efficiency is poor.

Removable quantification method: smear and count in liquid scintillation counter

Personal dosimeter: none required

 

NUCLIDE: P-32

TYPE(S) OF RADIATION
ENERGY
PERCENT DISINTEGRATION
RANGE IN AIR
RANGE IN WATER
SHIELDING REQUIRED






Beta
1.71 MeV (max)
100%
790 cm
0.76 cm
 1 cm Plexiglass


Physical half-life: 14.3 days

Survey instruments: GM survey meter

Removable quantification method: smear and count in liquid scintillation counter

Personal dosimeter: Whole body and extremity dosimeters
 

NUCLIDE: P-33

TYPE(S) OF RADIATION
ENERGY
PERCENT DISINTEGRATION
RANGE IN AIR
RANGE IN WATER
SHIELDING REQUIRED






Beta
249 keV (max)
100%
49 cm
0.6 mm
Plexiglass shielding reduces dose, but for microcurie amounts none is required

 
Physical half-life: 25.4days

Survey instruments: GM survey meter

Removable quantification method: smear and count in liquid scintillation counter

Personal dosimeter:  Whole body and extremity dosimeters for higher activities
 

NUCLIDE: I-125

TYPE(S) OF RADIATION
ENERGY
PERCENT DISINTEGRATION
SHIELDING REQUIRED




Te K X-rays
27-32 keV
140 %
Half-value-layer is 0.02 mm Pb

Gamma

35 keV

7% emitted;

93% internally converted

 
Physical half-life: 60.2 days


Volatility (@STP): substantial in disassociated form or in acidic solutions

Survey instruments: thin-window NaI scintillator; GM survey meter is less efficient.

Removable quantification method: smear and count in liquid scintillation counter or gamma counter

Personal dosimeter:  Whole body and extremity dosimeters for higher activities


 

George MacDurmon

University Radiation Safety Officer

127 Biomedical Sciences Building

940 Stanton L. Young Boulevard

Oklahoma City, OK    73190

Office:  (405) 271-6121

Fax:      (405) 271-1768 (fax)



This web site Designed and Built by Information Design Services a department of the University of Oklahoma Health Sciences Center.

Every effort will be made to update the information contained on these pages as necessary. However, it is the responsibility of the user to determine that he or she is relying on the most current version of any particular information. Any questions about the material should be directed to the referenced office or department.
    
Copyright © 2003 The Board of Regents of the University of Oklahoma, All Rights Reserved.
Disclaimer | Copyright